indirect reheat performance |
Model |
Reheat Time |
Coil kW Rating |
60 |
11 minutes |
16.5kW |
90 |
13 minutes |
16.5kW |
120 |
17 minutes |
16.5kW |
150 |
17 minutes |
18.9kW |
180 |
21 minutes |
18.9kW |
210 |
22 minutes |
18.9kW |
250 |
28 minutes |
21.4kW |
300 |
36 minutes |
21.4kW |
|
|
The reheat performance is measured from 15°C to 60°C after drawing off 70% of the capacity.
The coil kW rating is a guide to the minimum size of boiler required to achieve the reheat times stated.
|
direct reheat performance |
Model |
Reheat Time |
Coil kW Rating |
| |
one element |
two elements |
60 |
45 minutes |
- |
90 |
35 minutes |
- |
100 |
58 minutes |
- |
120 |
90 minutes |
45 minutes |
150 |
121 minutes |
62 minutes |
180 |
157 minutes |
79 minutes |
210 |
192 minutes |
96 minutes |
250 |
224 minutes |
112 minutes |
300 |
263 minutes |
132 minutes |
|
| |
immersion heaters |
| Tribune is fitted with Immersion Heater as follows: |
| Size |
Direct |
Indirect |
Twin Coil |
| 90 Litre |
One Immersion Heater |
One Immersion Heater |
Not Made |
| 120 Litre |
Two Immersion Heaters |
One Immersion Heater |
Not Made |
| 150/180/210 Litre |
Two Immersion Heaters |
One Immersion Heater |
One Immersion Heater |
| 250/300 Litre |
Two Immersion Heaters |
Two Immersion Heaters |
One Immersion Heater |
|
| |
flow rates |
|
Tribune Unvented Pressure V Flow Performance (measured at 50% Backpressure to simulate the effect of the drawoff pipework and taps)