indirect reheat performance


Model
Reheat Time
Coil kW Rating
60
11 minutes
16.5kW
90
13 minutes
16.5kW
120
17 minutes
16.5kW
150
17 minutes
18.9kW
180
21 minutes
18.9kW
210
22 minutes
18.9kW
250
28 minutes
21.4kW
300
36 minutes
21.4kW

The reheat performance is measured from 15°C to 60°C after drawing off 70% of the capacity.
The coil kW rating is a guide to the minimum size of boiler required to achieve the reheat times stated.

direct reheat performance


Model
Reheat Time
Coil kW Rating
 
one element
two elements
60
45 minutes
-
90
35 minutes
-
100
58 minutes
-
120
90 minutes
45 minutes
150
121 minutes
62 minutes
180
157 minutes
79 minutes
210
192 minutes
96 minutes
250
224 minutes
112 minutes
300
263 minutes
132 minutes
 

immersion heaters

Tribune is fitted with Immersion Heater as follows:

Size Direct Indirect Twin Coil
90 Litre One Immersion Heater One Immersion Heater Not Made
120 Litre Two Immersion Heaters One Immersion Heater Not Made
150/180/210 Litre Two Immersion Heaters One Immersion Heater One Immersion Heater
250/300 Litre Two Immersion Heaters Two Immersion Heaters One Immersion Heater
 

flow rates


Tribune Unvented Pressure V Flow Performance
(measured at 50% Backpressure to simulate the effect of the drawoff pipework and taps)

< Back to Tribune HE | Next