installation
Regulations
All unvented units with a capacity over 15L
capacity must be installed by a competent
installer in accordance with the following
Regulations:
England and Wales - Building Regulation G3
Scotland - Technical Standard P3
N Ireland - Building Regulation P5
Siting
With no header tanks to consider, Tribune HE
units can be sited almost anywhere in the
house. Tribune HE can supply outlets both
above and below its location. Tribune HE must
be fixed VERTICALLY on a flat surface capable of
holding its weight.
Water Supply
An adequate water supply is vital to ensure
Tribune HE produces the high performance of
which it is capable. We recommend a minimum
supply of 1.0 bar with a flow rate of 25
litres/min. The maximum supply pressure is 16
bar.
Compatible Boilers
Gas or oil fired fitted with an integral control
thermostat and cut-out. Any heat source that
lacks full thermostatic control such as most solid
fuel boilers, Agas, Rayburns and Stanleys
cannot normally be connected to any unvented
system.
The Primary circuit may be Open Vented or Sealed (operating at up to 7 bar). The primary circuit
must be pumped.
Connection Sizes
Cold Inlet - 22mm compression.
Hot Outlet - 22mm compression.
Coil connections - 22mm compression.
Safety Valves - 15mm compression outlet.
Inlet Control Set - 22mm compression inlet and outlet.
Tundish - 15mm compression inlet / 22mm compression outlet.
Secondary Return
A dedicated 22mm secondary return connection is fitted to 210, 250 and 300 litre sizes. A swept
tee (not supplied) could be used to provide a secondary return on the smaller sizes.
Electrical Wiring
Controls should be wired to the boiler / programmer etc. in accordance with the control scheme
being used. Although compatible with Y, W or S Plan layouts, Tribune HE units are perhaps best
suited to installation as an S Plan since we already supply one of the two port valves necessary,
so reducing installation costs compared to other plans.
Each immersion heater must have a permanent connection via a double pole-linked isolating
switch with a minimum rating of 13 amps. All electrical wiring must comply with the latest IEE
wiring regulations.
|