ultracal

A British standard 1566 ultra high performance double feed indirect system cylinder with Corrosion Resistant Technology. For use in an open vented hot water system.

Primary Sytems
Ultracal is not suitable for gravity circulation.
Ultracal is suitable for pumped circulation only, and is capable of reheating from 10 to 60oC in 15 mins.

Ultracal is suitable for sealed primary systems operating at up to 3.5 bar. Primary coils with higher pressure ratings are available.

Reheat times assume that the primary flow is maintained at 82oC at a flow rate of approx 18 l/min.

Grade
available in 3 grades to suit the following working head.

Grade 3
10m
Grade 2
15m
Grade 1
25m

Insulation
Ultracal has a single thickness of C.F.C free urethane foam lagging as standard, this adds approximately 50mm to the cylinder diameter.
Ultracal is available with a double thickness of C.F.C free urethane foam lagging on request, this gives lower heat loss, and will add approximately 100mm to the cylinder diameter.

Size of screwed connections
(fitted as standard)

BS Ref.
Secondary Connections
Primary Coil Connections
0-9
G1" Female
G1" Male

If you require G/4 or 1/4" connections these are available at no extra cost - please inform us at the time of order.

Male screwed secondary connections are available to order. Ultracal cylinders are fitted with compression fittings as standard. As follows.

Size of compression connections
Ultracal cylinders are fitted with compression fittings as standard.
As follows:

BS Ref.
Secondary Connections
Primary Coil Connections
0-2
22mm
22mm
3-9
22mm
28mm

Thermostat Boss

A 1/2" female thermostat boss can be factory fitted at no extra charge if requested. This allows the use of an insertion type thermostat which gives a quicker response than strap on types. We can supply a Honeywell 6188B insertion thermostat to customer order.

We recommend the use of an insertion type thermostat when small capacity Ultracal's are heated by powerful boilers. i.e. When a 60 or 80 litres Ultracal is heated with boilers of 80,000 BTU or more.

  • 6 Year Guarantee
  • 15 Minute Recovery Time*
  • Corrosion Resistant Technology

 


BS ref.
Unlagged Height
Unlagged Diameter
Capacity
Heat Surface
Height of connections (from base)
 
A
B
   
H
J
M
 
mm
mm
litres
m2
mm
mm
mm355
-
600
350
45
0.52
600
75
375
-
600
400
62
0.61
400
75
445
-
750
400
80
0.79
550
75
445
2
900
400
96
0.97
700
75
595
3
1050
400
114
1.23
800
75
595
7
900
450
117
1.23
700
75
595
8
1050
450
140
1.23
800
75
595
9
1200
450
162
1.23
950
75
595

*Larger sizes are not available, please select from the Supercal range.