primatic

EA single feed indirect cylinder. For use in an open vented hotwater system.

Primary Sytems
Primatic is suitable for gravity circulation and will typically reheat from 10 to 60oC in 60 mins

Primatic is suitable for pumped circulation and is capable of reheating from 10 to 60oC in 30 mins

Primatic is not suitable for sealed primary systems.

Installations incorperating Primatic units should not have any form of inhibitor added to the primary system.

Grade
Available in 2 grades to suit the following working head.

Grade 3
10m
Grade 2
15m

Insulation

Primatic has a single thickness of C.F.C free urethane foam lagging as standard, this adds approximately 50mm to the cylinder diameter.
Primatic is available with a double thickness of C.F.C free urethane foam lagging on request, this gives lower heat loss and will add approximately 100mm to the cylinder diameter.

Primary capacity/Boiler ratings
Standard models (BS class 110):suitable for use with gravity or pumped circulation on installations with total primary volume i.e. contents of boiler, radiators and primary pipework, plus 4.5 litres (one gallon) for the "Primatic" unit up to a maximum of 110 litres (24 gallons).

Size of screwed connections
(fitted as standard)

BS Ref.
Secondary Connections
Primary Coil Connections
ALL
G1" Female
G1" Male

Male screwed secondary connections are available to order. Primatic units are not available with compression connections. Side entry immersion heater bosses are available to order.

Data Sheet
A data sheet on Primatic cylinders is available upon request.

BS ref.
Unlagged Diameter
Unlagged Height
Capacity
Heat Surface
Height of connections (from base)
 
 
A
B
   
C
D
E
 
mm
mm
litres
m2
mm
mm
mm
-
900
400
92
0.63
100
140
178
7
900
450
108
0.66
100
140
230
8
1050
450
130
0.78
100
140
305
9
1200
450
152
0.91
100
140
380

© 2006 Range Cylinders Limited.