solarmax hercal
Installation of solar cylinders can now be grant assisted.*
30% of the volume is dedicated solar capacity, and 70% volume can be heated in the normal
way via a primary coil on days when solar input is not sufficient to heat the full contents
of the unit or on days when additional energy is required.
Two control thermostats are used to maximise solar gain. The upper one is used for boiler
control (not supplied). The lower one is for solar control (not supplied). The upper 1/2"
female boss (G) is for a temperature gauge (not supplied).
The range shows seven popular sizes and capacities. When calculating the size required,
please ensure that the upper coil volume is used for total requirement. If the application
is for a twin bath, for example, at least 145 litre of 'upper coil' volume is required
so that this demand can be catered for on winter days.
The range shown here has a Part L complaint upper coil fitted.
The Solarmax coil can also be used for geotherm or alternative fuel input.
*Ask for more more information.
Dimensions
| A |
Height |
1200 |
1200 |
1500 |
1350 |
1500 |
1800 |
1800 |
| B |
Diameter |
400 |
450 |
400 |
450 |
450 |
450 |
500 |
| |
Capacity (Litres) |
131 |
160 |
166 |
180 |
206 |
250 |
300 |
Connections
| A |
HWDO
22mm Comp (28 on 250L & 300L) |
1200 |
1200 |
1500 |
1350 |
1500 |
1800 |
1800 |
| B |
Cold Feed
22mm Comp (28 on 250L & 300L) |
110 |
110 |
110 |
110 |
110 |
110 |
110 |
D |
Solar Coil
22mm Comp (fitted using mech conns) |
110 |
110 |
110 |
110 |
110 |
110 |
110 |
| E |
Solar Coil
22mm Comp (fitted using mech conns) |
190 |
190 |
190 |
190 |
190 |
190 |
190 |
| F |
Stat
1/2" BSP F (c/w Pock 10) |
200 |
200 |
200 |
200 |
200 |
200 |
200 |
| G |
Fossil Coil
1" BSP M (c/w Alnitec Set) |
400 |
400 |
500 |
450 |
500 |
600 |
600 |
| H |
Fossil Coil
1" BSP M (c/w Alnitec Set) |
300 |
370 |
370 |
370 |
440 |
440 |
520 |
| I |
Stat
1/2" BSP F (c/w Pock 10) |
990 |
990 |
1300 |
1150 |
1300 |
1500 |
1500 |
| J |
Sec Return
22mm Comp (on 206L, 250L & 300L) |
N/A |
N/A |
N/A |
N/A |
1300 |
1500 |
1500 |
| K |
Immersion Heater |
Top Dome |
Specification
| Solar Coil Detail |
Solarmax 18 |
Solarmax 32 |
| Fossil Coil Detail (319 Dia) |
5m x 28mm |
6m x 28mm |
6m x 28mm |
7m x 28mm |
8m x 28mm |
9m x 28mm |
11m x 28mm |
| Material Details (Top/Body/Bottom) |
0.9 / 0.9 / 1.6 |
1.2 1.2 / 1.8 |
| Product Codes |
2380 |
2381 |
2384 |
2382 |
2383 |
2386 |
2389 |
| Foam Insulation |
Double Thickness |
* All dimensions are in mm.
|