hercal
A British standard 1566 double feed indirect system cylinder. For use in an
open vented hot water system.
Primary Sytems
Hercal is not suitable for gravity circulation in its standard form
Hercal is suitable for pumped circulation, and
is capable of rehating from 10 to 60oC in 25 mins
Hercal is suitable for sealed primary
systems operating at up to 3.5 bar. Primary coils with higher pressure ratings are available.
Reheat times assume
that the primary flow is maintained at 82oC at a flowrate of approx 15 l/min
Grade available in 3 grades to suit the
following working head.
Grade 3 |
10m |
Grade 2 |
15m |
Grade 1 |
25m |
Insulation Hercal has a single thickness of C.F.C free
urethane foam lagging as standard, this adds approximately 50mm to the cylinder diameter. Hercal
is available with a double thickness of C.F.C free urethane foam lagging on request, this gives lower
heat loss and will add approximately 100mm to the cylinder diameter.
Size of screwed connections (fitted as standard)
BS Ref. |
Secondary Connections |
Primary Coil Connections |
0-9E |
G1" Female |
G1" Male |
10-11 |
G11/2 Female |
G1/4 Male |
12-14 |
G2" Female |
G11/2 Male |
Size of compression connections 22mm or 28mm integral compression connections are available at
extra cost on sizes 0-11 only. Sizes 12-14 not available.
- 25 Min Recovery Time*
- 25mm CFC Free Insulation
- Manufactured to BS1566
*The secondary return connection (H) is not fitted on sizes 0-9E unless requested.
A side entry immersion heater boss is available on request.
|