direct - fortic f1 super seven
A BS 3198 Direct combination cylinder
| Dimensions in mm |
|
|
|
|
|
|
litres |
| Nominal |
Height |
Diameter |
A |
B |
C |
D |
Hot |
Cold |
| |
|
|
|
|
|
|
|
900 |
400 |
615 |
300 |
535 |
265 |
65 |
15 |
900 |
450 |
610 |
300 |
500 |
275 |
85 |
20 |
1075 |
450 |
790 |
440 |
700 |
275 |
115 |
20 |
1200 |
450 |
790 |
440 |
700 |
400 |
115 |
40 |
1300 |
450 |
890 |
535 |
800 |
400 |
130 |
40 |
1400 |
450 |
985 |
440 |
900 |
400 |
144 |
40 |
1850 |
450 |
1435 |
890 |
1350 |
400 |
210 |
40 |
900 |
500 |
638 |
362 |
558 |
245 |
115 |
20 |
1200 |
500 |
800 |
400 |
720 |
370 |
145 |
45 |
1700 |
500 |
676 |
368 |
596 |
1007 |
115 |
160 |
1700 |
500 |
918 |
440 |
838 |
766 |
160 |
115 |
2050 |
500 |
676 |
368 |
596 |
1359 |
115 |
228 |
Drain boss centre above base
100mm.
Immersion heater dimensions 'G' -
115mm except those sizes marked*
where 'G' is '50mm.
Insulation
Fortic F1 has a single thickness of
C.F.C free urethane foam lagging as
standard, this adds approximately
50mm to the cylinder diameter.
Fortic F1 is available with a double
thickness of C.F.C free urethane foam
lagging on request, this gives lower
heat loss and will add approximately
100mm to the cylinder diameter.
|
|
|
© 2006 Range Cylinders Limited.
|
|
|