domestic selection guide

These recommendations are based on the guidelines in BS 6700.
Guidance should be sought for unusual applications. Eg: High flow - rate showers, large baths etc.

Hot Water Demand Bedrooms Indirect Direct
1 Bathroom or Shower Bedsit/1 Bed
2-3 Bed
3-4 Bed
SI90
SI190
SI150
SD120
SD150
SD210
1 Bathroom with corner bath 2-3 Bed
3-4 Bed
SI150
SI150
SD180
SD210
2 Bathrooms or Bath and Ensuite 2-3 Bed
3-4 Bed
4-5 Bed
SI150
SI180
SI210
SD180
SD210
SD250


Hot Water Demand Bedrooms Indirect Direct
1 Standard Bath + 1 Corner Bath 2-3 Bed
3-4 Bed
4-5 Bed
SI210
SI250
SI300
SD300
SD300
SD300
3 Bathrooms 3-4 Bed
4-5 Bed
5-6 Bed
SI150
SI150
SD180
SD210
Most showers fed from a Tribune will consume the same amount of hot water as a bath.

Reheat Performance

Indirect

Model Reheat Time Coil kW Rating
SI90 13 Minutes 6.5 kW
SI120 17 Minutes 16.5 kW
SI150 17 Minutes 18.9 kW
SI180 21 Minutes 18.9 kW
SI210 22 Minutes 18.9 kW
SI250 28 Minutes 21.4 kW
SI300 36 Minutes 21.4 kW

Direct

Model Reheat Time
One Element
Reheat Time
Two Elements
SD90 58 Minutes -
SD120 90 Minutes 45 Minutes
SD150 121 Minutes 61 Minutes
SD180 157 Minutes 79 Minutes
SD210 192 Minutes 96 Minutes
SD250 224 Minutes 112 Minutes
SD300 263 Minutes 132 Minutes

The reheat performance is measured from 15°C to 60°C after drawing off 70% of the capacity. The coil kW rating is a guide to the minimum size of boiler required to achieve the reheat times stated. Faster reheat times are achieveable using twin - coil Tribunes. With both coils fed simultaneously, reheat times can be reduced to almost half. The boiler power required would double.

Specification

Inner Container Duplex 2304 stainless steel to EN 10088.4362.

Primary Coil 22mm diameter 36L stainless steel. Coil in coil design for improved performance. Entire cylinder contents are heated on indirect models. The primar y system must be fully pumped. The primar y circuit may be sealed (max. 7 bar).

Outer Casing (optional) Zintec corrosion proofed steel with durable oven - hardened white paint finish.

Thermal Insulation Fire retardant polyurethane foam. The foam is CFC free, HCFC free and has an Ozone depletion potential of zero. Nominal thickness 50mm

Immersion Heater Supplied on all units. 1.75" BSP parallel threaded head. Long life incoloy sheathed low noise element 14" long. Long life incoloy sheathed thermostat pocket 11" long. Brazed construction. 11" combined thermostat and safety cut - out. Element rating 3Kw at 240V A/C.

Installation

Fixing The units must be fitted vertically.

Water Supply The unit must be used on an open vented system (ie. fed from a cold water tank and fitted with a vent pipe). The maximum working head is 40m.

Plumbing Connections Inlet / outlet - 22mm compression. Indirect coils - 22mm compression. Thermostat / Shower tapping - 1/2"F.

*NOTE Use D2R / Gunmetal compression fittings to make connections onto the 22mm stub pipes.

Do not use push - fit connectors.