direct
A British standard 1566 direct cylinder. For use in an open vented hot water system.
Grade available in 3 grades to suit the following working head.
Grade 3 |
10m |
Grade 2 |
15m |
Grade 1 |
25m |
Reheat Performance
The reheat times shown in the table are the time taken to raise the entire contents of the cylinder from 10 to 60oC using a single 3kW immersion heater.
For faster reheat performance we can supply 6kW and 9kW immersion heaters to customer order.
Insulation
Direct has a single thickness of C.F.C free urethane foam lagging as standard, this adds approximately 50mm to the cylinder diameter.
Direct is available with a double thickness of C.F.C free urethane foam lagging on request, this gives lower heat loss and will add approximately 100mm
to the cylinder diameter.
Size of screwed connections (fitted as standard)
BS Ref. |
|
0-9E |
G1" Female |
10-11 |
G11/2 Female |
12-14 |
G2" Female |
If you require G11/4" connections these are available at no
extra cost - please inform us at the time of order.
Male screwed secondary connections are available to order.
Size of compression connections
22mm or 28mm integral compression connections are available at extra cost.
- Manufactured to BS1566
- 25mm CFC Free Insulation
- Suitable for 3, 6 & 9Kw Immersion Heaters
BS ref. |
Unlagged Diameter |
Unlagged Height |
Capacity |
Height of connections (from base) |
Reheat Time |
|
A |
B |
|
H |
L |
|
|
mm |
mm |
litres |
mm |
mm |
|
- |
1500 |
300 |
98 |
1250 |
100 |
1h 54m |
2 |
900 |
400 |
98 |
700 |
100 |
1h 54m |
3 |
1050 |
400 |
116 |
800 |
100 |
2h 15m |
4 |
675 |
450 |
86 |
450 |
100 |
1h 40m |
5 |
750 |
450 |
98 |
550 |
100 |
1h 54m |
6 |
825 |
450 |
109 |
625 |
100 |
2h 7m |
7 |
900 |
450 |
120 |
700 |
100 |
2h 20m |
8 |
1050 |
450 |
144 |
800 |
100 |
2h 48m |
9 |
1200 |
450 |
166 |
950 |
100 |
3h 13m |
9E |
1500 |
450 |
210 |
1250 |
100 |
4h 4m |
10 |
1200 |
500 |
200 |
950 |
150 |
3h 53m |
11 |
1500 |
500 |
255 |
1200 |
150 |
4h 57m |
12 |
1200 |
600 |
290 |
950 |
150 |
5h 38m |
13 |
1500 |
600 |
370 |
1200 |
150 |
7h 12m |
14 |
1800 |
600 |
450 |
1450 |
150 |
8h 46m |
*The secondary return connection (H) is not fitted on sizes
0 - 9E unless requested.
A side entry immersion heater boss is available on request.
|